• service line: +86 752-3500910
  • Email: ming.wu@szmcdw.com
LMxxx
LCxxx
LDxxx
LDxxx2
LWxxx
LMxxx
LCxxx
LDxxx
LDxxx2
LWxxx

LRQ Tester

Product Description

Automatic and manual optional

Inductance, leakage, capacitance testing

Novel MR, MIα, MIβ test functions to improve measurement accuracy

Powerful data analysis, Gerber data map, scan code function

Marking function improves the visualization of test PASS and FAIL viewing

Scope Of Application
Technical Specifications
Video Show
电感01
电感02
电感03
电感04
电感05
电感06
电感07
电感08
电感09
电感10
电感11
电感12
电感13
电感14
电感15
电感16
电感17
电感18
电感19
电感20
电感21
Inductance tester parameter
Parameter        
P/N LMxxx LCxxx LDxxx LWxxx
System type Manual Manual/Auto Manual/Auto Manual/Auto
Number of test points (optional multiple of 25) 200-400 100-2300 100-2300 100-2300
Maximum test area (special size can be customized) 320*320mm Manual: 500*500mm Manual: 720*650mm Manual: 750*750mm
Double arm automatic: 450*400mm Single arm automatic: 400*380mm Double arms 650*550mm
Minimum test area 30*30mm Manual: 30*30mm 30*30mm 30*30mm
Auto: 100*100mm Auto: 100*100mm 250*200mm
Bad board draw line marking function None Optional Optional Optional
Visual inspection function of bad board drawing line mark None Optional Optional Optional
QR code scanning method Optional single and double sided Optional single and double sided Optional single and double sided Optional single and double sided
Test accuracy implementation standard JJG441-2008 JJG837-2003
Fixture specifications MCDW LRQ FIXTURE & MCDW MI FIXTURE
A needle method 4-wire type
Inductance measurement range 0.15uH-9999.9H
Resistance measurement range 0.1mΩ-99.9MΩ
MI measurement accuracy Level 1-5
Test level 5mV-2V
Test frequency 20Hz-500KHz
Test efficiency Auto>450SET/H
Report save information Test time/Nominal value of leakage current&Measurement value/Result type
Method of distinguishing test unit GBERER vector map & manual cell division
MR test function Standard configuration
Manual cell division 48 rows*48 columns
Bad board tracking Display&print&database save
Operating system Windows
Data input/export USB&LAN
Test temperature 20-26°C
Test humidity 40%-70% (non-condensing)
Air pressure requirement 0.6-0.8MPa
Voltage requirements 220V±10%
Automatic scanning of QR code matching report and MES connection Requires optional scan code function to execute
Dimensions 1.2*0.9*1.7M 3.8*1.45*1.8M 3*1.1*1.75M 4.2*1.75*1.75M
Auto test video
Scan code video
Marking machine