HI-Pot Tester

Product Description

Mainly include aluminum substrates, energy boards, power boards, secondary power supplies, automotive boards, etc.

Manual and automatic optional

Multi-source synchronization test (1~10 sources are optional)

AC 5KV, DC 6KV can be measured

Powerful data analysis, Gerber data graphs, scan code function (SPC, Rea-Time voltage)

The number of single source test points can be expanded arbitrarily (4~128)

Marking function improves the visualization of test PASS and FAIL viewing

Scope Of Application
Technical Specifications
Video Show
耐压15
耐压14
耐压13
耐压12
耐压11
耐压10
耐压09
耐压08
耐压07
耐压06
耐压05
耐压04
耐压03
耐压02
耐压01
Hi-pot tester parameter
Parameter        
P/N HMxxx-x HCxxx-x HDxxx-x HWxxx-xx
System type Manual Manual/Auto Manual/Auto Manual/Auto
Number of channels 8-64 channels 8-128 channels 8-128 channels 8-320 channels
Number of simultaneous analysis sources (the last X of the model) (1-8) (1-8) (1-8) (1-10)
Maximum test area (special size can be customized) 320*320mm Manual: 500*500mm Manual: 720*650mm Manual: 750*750mm
Double arm automatic: 350*400mm Single arm automatic: 400*450mm Double arms 650*550mm
Minimum test area 30*30mm Manual: 30*30mm 30*30mm 30*30mm
Auto: 100*100mm Auto: 100*100mm 250*200mm
Bad board draw line marking function None Optional Optional Optional
Visual inspection function of bad board drawing line mark None Optional Optional Optional
QR code scanning method Optional single and double sided Optional single and double sided Optional single and double sided Optional single and double sided
Probe contact check function Standard configuration
Test accuracy implementation standard JJG 795-2016 JJG 1005-2005 (passed third-party certification)
Fixture specifications MCDW HV FIXTURE
A needle method 2TEST PIN 1CH=2TEST PIN
AC voltage measurement range (AC) AC 100V-5000V
DC voltage measurement range (DC) DC 50V-6000V
Insulation resistance voltage measurement range (IR) Insulation resistance 50V-1000V
AC leakage current test range (AC) 0-20mA
DC leakage current test range (DC) 0-10mA
Arc measurement range (ARC) 2.8mA-20mA (grade 1-9) grade and value are optional
Report save information Test time/Nominal value of leakage current&Measurement value/Result type
Method of distinguishing test unit GBERER vector map & manual cell division
Voltage rise time 0.1-1000S
Test time 0.1-1000S
Voltage fall time 0.1-1000S
Manual cell division 48 rows*48 columns
Bad board tracking Display&print&database save
Operating system Windows
Data input/export USB&LAN
Test temperature 20-26°C
Test humidity 30%-50% (non-condensing)
Air pressure requirement 0.6-0.8MPa
Voltage requirements 220V±10%
Automatic scanning of QR code matching report and MES connection Requires optional scan code function to execute
Dimensions 1.2*0.9*1.7M 3.8*1.45*1.8M 3*1.1*1.75M 4.2*1.75*1.75M
Scan code video
Auto test video